British Gas 330 boiler | PlumbersForums.net

Dec 01, 2021 · Anyone know what glow worm this is? It's about 7/8 years old looks like a Saunier duvall f24/30 TBH. Discuss British Gas 330 boiler in the Central Heating Forum area at PlumbersForums.net. Reply to British Gas 330 boiler in the Central Heating Forum area at PlumbersForums.net.

Get Price

British Gas 330 (Glow Worm) | PlumbersForums.net

Apr 19, 2012 · Apr 15, 2012. #1. Hi, I have a British Gas 330 condensing boiler (manufactured by Glow Worm). I've been plasterboarding today and removed the downstairs light fitting and although the downstairs lighting circuit was off at the consumer unit I think because I touched the neutral and earth together the whole upstairs circuit RCD tripped.

Get Price

BG 330+ fitting new Hive, hot water ok, no heating

Dec 03, 2015 · BG 330+ (Glow worm re-badged) RC Plus wireless thermostat in hall. Timer/control Model UT2 in cupboard upstairs with hot water tank. Boiler downstairs in Kitchen. New setup/addition: BG Hive thermostat - dual channel heating and hot water. I bought the new Hive 2 kit for 'heating and hot water'. I unclipped the timer/control UT2 and clipped the

Get Price

Too much air in British Gas Glow Worm 330 boiler - MyBuilder

Too much air in british gas glow worm 330 boiler I have a Bristish Gas 330 boiler which is a Glow Worm boiler. AA emergency cover have been out 4 times and so far they have changed the pump but basically drawn a blank as to why it won't work.

Get Price

What's a BG 330 - Screwfix Community Forum

Jul 29, 2009 · From BG; A compact, A-rated condensing boiler, the BG330 is exclusive to British Gas and manufactured by GlowWorm. The BG330 is a discreet addition to any sized home and offers powerful flexible output that will adapt to a home s changing needs. With a Sedbuk A rating, this condensing boiler ensures energy efficiency and lower energy bills.

Get Price

BRITISH GAS 330 INSTRUCTIONS FOR USE INSTALLATION AND

Advantica. 330 HIGH EFFICIENCY CONDENSING BOILER 1.5 Condensate Drain GC No. 41-047-75 Manufactured exclusively for British Gas by Glow-worm TYPE : 230V~50Hz 60W fused at 3A For use on A plastic drain pipe must be fitted to allow discharge of

Get Price

how to turn gas back on british gas

Dec 17, 2021 · How do I set a British Gas RC1 Themostat | DIYnot Forums Back to British Gas hub. We don't let british gas through the door anymore. Initially, the loss of heating and hot water was put down to a faulty boiler. scatmanjohn. A savvy couple has renovated a British Gas van into a quirky home for £5,000.

Get Price

Boiler Replacement by British Gas £3700 - Page 7

May 06, 2014 · I had last week arranged an appointment with a British Gas salesmen regarding possibly replacing our 17 year old boiler.

Get Price

Glow-Worn Boiler F13 Fault Code - EPHG Limited

When your Glow-Worm boiler shows a fault code on the display panel, it helps your repair company to quickly diagnose the fault. Rather than having to fault find every component in your boiler, they're pointed towards a specific problem. In the case of the F13 fault code, the problem lies with the printed circuit board (PCB).

Get Price

British Gas 330 boiler - F5 error code? = Answered | Mend

It means your boiler is overheating. I'm just getting mine repaired it requires new gaskets but an F5 could equally be be some other cause so I'm told. If you are in London try Permaguard tel. 08448400888 they are sorting me out. Huge. February 2010. Hi it's an over heat problem Turn off electrical supply.

Get Price

Brtish Gas 330 (glow worm) boiler faults | Talk

Oct 31, 2010 · Had a leaking rad so changed it a few weeks ago, over the past few days the boiler has been chucking up F1 & F5 faults. Sometimes I can hear water trickling (gurgling) in the pipe above the boiler. Had BG out as part of the home care pack & …

Get Price

How to reset boiler after power cut Glow worm 330 or 350

Dec 28, 2013 · Discuss How to reset boiler after power cut Glow worm 330 or 350 in the Plumbing Forum Pretty sure the 330 is a re-branded BG boiler, just the old HXi I think. Reply to How to reset boiler after power cut Glow worm 330 or 350 in the Plumbing Forum | Plumbing Advice area at PlumbersForums.net. Similar threads. S.

Get Price

F13 glow worm boiler fault? = Answered | Mend Heating

F13 glow worm boiler fault? Hi i have a 18hxi boiler and the f13 fault which is main pcb board fault. when the heating it turned off in the morning the f13 is there. if you put the heating on and the f13 is there and i bang the front panel it starts to work. i have check all the wires is it the main board all seems ok??? as i dont want to buy one it is wont sort the problem out.

Get Price

Glow Worm Boiler Problem — boards.ie - Now Ye're Talkin'

Dec 03, 2008 · I live in a 2-bed townhouse with the dodgy 18si boiler also. Heres one thing you can try. We started getting that F1 fault in the summer cos we had turned down the thermostat but left the boiler at a very high rate, apparently this can cause the pilot to drop out. Check the settings on the front of the boiler.

Get Price

Boiler Replacement: Quotes | Screwfix Community Forum

Aug 06, 2008 · Lunk, the 330 is a glowworm hxi boiler, i fit these on my own job and have always been very good, i have not had a call back yet (yes i just said that ) but we all have our favorites, The system needs a good clean as the water ways though the boiler are quite small on the boiler and could get blocked .

Get Price

BG 330+ No Expansion Vessel | Screwfix Community Forum

Jan 07, 2016 · We have a BG 330+ Condensing Boiler installed in the loft. Given that the CH system has a filling loop (in the loft) and that the only water tank is also in the loft (below the height of the boiler) I believe its a sealed system. However, I cannot find an expansion vessel or pressure gauge anywhere on the system (except the digital display on

Get Price

Glowworm BG 330 boiler | DIYnot Forums

Dec 19, 2011 · DIYnot Forums. Home Forums > How to Glowworm BG 330 boiler. Discussion in 'Plumbing and Central Heating' started by Tarby25, 18 Dec 2011. Page 1 of 2 1 2 Next > Tarby25. Joined: 13 Jan 2010 This is a British gas boiler rather than a standard glowworm.

Get Price

British Gas 330 Boiler Locking Out ! | PlumbersForums.net

Jan 13, 2012 · We have a British Gas 330 system boiler (not combi) which was installed about 3 years ago. Recently the boiler has been locking out (green burner light goes out) after running for about 10 minutes. This happens on hot water only, heating only …

Get Price

Condensing Vs. Non-Condensing Boilers: Which One Is Better

Non-condensing boilers send 20 percent of the available heat up the vent pipe to the outside. Condensing boilers use more sophisticated heat exchange technology to capture up to an additional 15 percent of that wasted heat. This recaptured heat …

Get Price

Glow Worm Flexicom Fault Codes F4 & F22 Easily Fixed in 5 mins

I recently had an issue with my Glow Worm Flexicom 12hx boiler which led to fault codes F4 and F22 being displayed on the screen. The solution was simple and only took me about 1o minutes to fix. Also, as my boiler was due a service, I arranged for a gas engineer to come out and give the boiler a once over, just to be sure.

Get Price

BG 330+ with F22 Dry error | DIYnot Forums

Oct 04, 2021 · DIYnot Forums. Home Forums > How to > Plumbing and Central Heating > Your boiler is made by Glowworm for BG and is mostly based on their GlowWorm Flexicom HX with maybe some influences from a GlowWorm Ultracom Sxi. British Gas 330+ boiler appears to be randomly heating the hot water.

Get Price

We have a British Gas 330+condensing boiler. Periodically

Dec 06, 2012 · We have a British Gas 330+condensing boiler. Periodically it makes a whooping sound from the top right side of boiler - Answered by a verified Plumber Still F1. On another forum suggestion (old) left electrodes exp Hi I Have a British Gas glow worm 330 condensing boiler fault F24 and then F10,reset it will start up and die F10 coming on

Get Price

Unable to increase pressure of BG 330+ boiler - …

Sep 03, 2019 · Country: I've got a sealed system in my house with a British Gas 330+ boiler (re-badged Glow-worm). Currently the boiler is reporting that the pressure is 0.3 bar but is still working. When attempting to increase the pressure using the filling loop a small amount of water enters the system for a few seconds and then stops and the pressure stays

Get Price

Boiler Replacement by British Gas £3700

Aug 01, 2008 · Thats for a replacement boiler BG Glowworm 330, a power flush, a wireless thermostat, and a few other bits and bobs like adding a new radiator thermostat. Although he was unable to break down how he came to the £3700 figure, i tried to do it for him. Apparently Boiler is around £1100, Labour £1900, Thermostat £150, plus VAT, plus all the

Get Price

Glowworm 40FF boiler won't ignite ( One for Seacam

Nov 14, 2018 · Quick update, Rechecked the boiler and its a Glowworm ultimate the GC number is ( having squinted at it long and hard this time with a torch) is 41-319-57, which as Roush implies above its a hepworth heating one,- sorry for the confusion,the engineer kept quoting the other one so quoted it here. although having gone over it thoroughly again the

Get Price

What fault does F5 indicate on a british gas 330 glowworm

Nov 07, 2012 · What fault does F5 indicate on a british gas 330 glowworm boiler - Answered by a verified Plumber We use cookies to give you the best possible experience on our website. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them.

Get Price

BG 330+ = which Worcester Bosch boiler | DIYnot Forums

Sep 03, 2019 · I've just had a quote from BG and their recommendation is a BG 330+ high efficiency boiler. The guy tells me that this is a BG badged Worcester Bosch boiler of about 30kW. When I look at the Worcester Bosch website there are a couple of boilers that could fit the bill namely the Greenstar 30CDi conventional and the Greenstar FS 30CDi Regular.

Get Price

Boiler Gas Valve Problems And Faults - Heating | Gas

On the flip side, gas valves for Glow-Worm boilers can be as cheap as £100. So, the cost of parts is going to have a direct impact on the cost of the overall valve replacement. If you require an emergency call out for your boiler repair, the cost can vary depending on the time you require an engineer to visit and the company your using in

Get Price

Glowworm 40FF boiler won't ignite ( One for Seacam

Nov 14, 2018 · Quick update, Rechecked the boiler and its a Glowworm ultimate the GC number is ( having squinted at it long and hard this time with a torch) is 41-319-57, which as Roush implies above its a hepworth heating one,- sorry for the confusion,the engineer kept quoting the other one so quoted it here. although having gone over it thoroughly again the

Get Price

Baxi Boiler - any good — Digital Spy

Jul 14, 2010 · The Baxi Duo-Tec is an excellent boiler. Try googling DIYNot, MSE or the Screwfix forum for some impartial advice. Never had a callback on a single one of them Do NOT buy the W-B junior range, they are the cheap contract model, the CDI is more expensive but far superior. But, hey, Seacam is the acknowledged and undisputed expert here

Get Price

How to reset boiler after power cut Glow worm 330 or 350

Dec 28, 2013 · Discuss How to reset boiler after power cut Glow worm 330 or 350 in the Plumbing Forum Pretty sure the 330 is a re-branded BG boiler, just the old HXi I think. Reply to How to reset boiler after power cut Glow worm 330 or 350 in the Plumbing Forum | Plumbing Advice area at PlumbersForums.net. Similar threads. S.

Get Price

Baxi Luna 3 Manual

BAXI Luna3 Boiler HydroHeat Supplies Hydronic Heating. Manual. BAXI LUNA 3 COMFORT OPERATION INSTRUCTIONS Pdf Download. Baxi Luna 3 Boiler DIYnot Forums. BAXI LUNA 3 COMFORT TROUBLESHOOTING MANUAL Pdf Download. Baxi User Manuals WordPress Com. Caldaia Baxi Luna 3 Avant 24 Kw Istruzioni D Uso. Baxi Boilers Gas Boilers And Award Winning …

Get Price

Too much air in British Gas Glow Worm 330 boiler - MyBuilder

Too much air in british gas glow worm 330 boiler I have a Bristish Gas 330 boiler which is a Glow Worm boiler. AA emergency cover have been out 4 times and so far they have changed the pump but basically drawn a blank as to why it won't work.

Get Price

Glow Worm combi boiler fault (Now Fixed

Aug 01, 2012 · Glow Worm combi boiler fault (Now Fixed) Not sure if this is the best forum but I have a fault (F12) on my Glow Worm CXi30 boiler. An engineer has come out and told me it would cost a minimum of £360 for parts + labour as the problem may be difficult to trace. I have phoned Glow Worm and a Fixed Cost Repair would cost £260, which seems

Get Price

BG 330+ No Expansion Vessel | Screwfix Community Forum

Jan 07, 2016 · We have a BG 330+ Condensing Boiler installed in the loft. Given that the CH system has a filling loop (in the loft) and that the only water tank is also in the loft (below the height of the boiler) I believe its a sealed system. However, I cannot find an expansion vessel or pressure gauge anywhere on the system (except the digital display on

Get Price

Loud Humming British Gas 300+ Boiler (& Dementia

Oct 18, 2015 · Morning All, I'm currently caring for Mum & Dad (both in their 80's with dementia) so I really don't need the added unhelpful input of their 300+ loud humming boiler if it could give me words of advice on how to help them, that would be different :-O I suppose it's when it's heating up. It's a very loud droning hum. I can temporarily stop it by reducing the temperature …

Get Price

Glow Worm Boiler Problem — boards.ie - Now Ye're Talkin'

Dec 03, 2008 · I live in a 2-bed townhouse with the dodgy 18si boiler also. Heres one thing you can try. We started getting that F1 fault in the summer cos we had turned down the thermostat but left the boiler at a very high rate, apparently this can cause the pilot to drop out. Check the settings on the front of the boiler.

Get Price

New Boiler - CORGIs barely cheaper than BG

Sep 23, 2008 · We currently have a Potterton Kingfisher conventional floorstanding boiler. Howdy, Stranger! It looks like you're new here. Sign in or register to get started.

Get Price

British Gas - 330 - FREE BOILER MANUALS

Condensing Boiler 0020008877-04 08.06 12373 G.C. No. 41-047-75 British Gas 330 Customer Care Line Tel: 0845 600 5100. 0020008877-04 2 MAINTENANCE INSTRUCTIONS INTRODUCTION INSTRUCTIONS FOR USE INSTALLATION INSTRUCTIONS Contents The instructions consist of three parts, User, Installation and Servicing Instructions.

Get Price

Cost of a replacement boiler — Digital Spy

Jul 10, 2006 · Cost of a replacement boiler. My father-in-law has just been quote by British Gas for a replacement boiler as his old one is on it's way out. They want just under £3,300 - and that includes having given him a £400 discount for his old boiler. For those who know anything about them (we can't find anything) it's an "Exclusive" British Gas 330

Get Price

British Gas 330+ - FREE BOILER MANUALS

Wiring to the boiler must be PVC 85OC insulated cable, not less than 0.75mm2 (24/0.20mm). Testing and Certification This boiler is tested and certificated for safety and performance. It is, therefore, important that no alteration is made to the boiler, without permission, in …

Get Price

Brtish Gas 330 (glow worm) boiler faults | Talk

Oct 31, 2010 · Had a leaking rad so changed it a few weeks ago, over the past few days the boiler has been chucking up F1 & F5 faults. Sometimes I can hear water trickling (gurgling) in the pipe above the boiler. Had BG out as part of the home care pack & …

Get Price

What's a BG 330 - Screwfix Community Forum

Jul 29, 2009 · From BG; A compact, A-rated condensing boiler, the BG330 is exclusive to British Gas and manufactured by GlowWorm. The BG330 is a discreet addition to any sized home and offers powerful flexible output that will adapt to a home s changing needs. With a Sedbuk A rating, this condensing boiler ensures energy efficiency and lower energy bills.

Get Price

BRITISH GAS 330 INSTRUCTIONS FOR USE INSTALLATION AND

Advantica. 330 HIGH EFFICIENCY CONDENSING BOILER 1.5 Condensate Drain GC No. 41-047-75 Manufactured exclusively for British Gas by Glow-worm TYPE : 230V~50Hz 60W fused at 3A For use on A plastic drain pipe must be fitted to allow discharge of

Get Price

british gas 330 (gloworm allegedly) - .ultimatehandyman

Jan 14, 2017 · Re: british gas 330 (gloworm allegedly) Post by gas4you » Fri Jan 13, 2017 8:08 am I have just looked it up on the manuals library and as long as I am looking at the correct boiler, BG330+ it is a re-badged glow worm with a stainless steel heat exchanger.

Get Price

How to wire thermostat to boiler ??? — MoneySavingExpert Forum

Jan 20, 2007 · In this booklet it gives instructions on removing the casing (fixing in reverse), locating the wiring positions, and which terminals to connect the two wires to. Instructions with your thermostat will indicate which wire to connect to the two terminals. Without the document to hand though its difficult to give any more info. 0.

Get Price

BG 330+ fitting new Hive, hot water ok, no heating

Dec 03, 2015 · BG 330+ (Glow worm re-badged) RC Plus wireless thermostat in hall. Timer/control Model UT2 in cupboard upstairs with hot water tank. Boiler downstairs in Kitchen. New setup/addition: BG Hive thermostat - dual channel heating and hot water. I bought the new Hive 2 kit for 'heating and hot water'. I unclipped the timer/control UT2 and clipped the

Get Price

British Gas 330 boiler - F5 error code? = Answered | Mend

It means your boiler is overheating. I'm just getting mine repaired it requires new gaskets but an F5 could equally be be some other cause so I'm told. If you are in London try Permaguard tel. 08448400888 they are sorting me out. Huge. February 2010. Hi it's an over heat problem Turn off electrical supply.

Get Price

How long can I expect a combi boiler to last

May 24, 2008 · 23 May 2008 at 7:04AM. Welcome to the forum. There have been several articles in the media about the inherent un-reliability of modern condensing boilers. Stuffed full of electronics, some informed opinion is that you will be very lucky to get 10 years life out of modern boilers; with breakdowns in that period.

Get Price

Glow-worm Boiler Problems, Repair Advice & How to Fix

Glow-worm boiler warranty. Glow-worm boilers come with 2-7 years of warranty as standard but some models are eligible for up to 15 years of warranty through Glow-worm's club energy installers. Find out more with our guide to Glow-worm warranties.