Leader boilers Home Facebook


Leader boilers Home Facebook

Leader boilers Home Facebook
  • Offshore price : $8,999.00 - $100,000.00
  • Minimum order quantity : 1 set
  • Supply Capacity : 10 units/month
  • Manufacturer/Brand : TOBO BOILER
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA
I need the quotation of for Ton/KW , the fuel is , use for ,My name is , my Email is ,my phone number is , Please Send the detail information for me!

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boiler replacement in average 3 bed semi, how much

In a place we rent out the gas boiler for the hot water/heating is playing up and has been for a while, it is pretty old, latest quote for repairs is £500+ eek, engineer says we'd be better off

Get Price

problem with Truma gas boiler | Practical Caravan Forums

Dec 22, 2007 · Hi, I have a 1994 motorhome fitted with a 1993 Truma Boiler for heating the water, the problem is, I have a constant green light on the control panel, I have the temerature dial on full to 70, yet the water only ever heats to about 15 degrees., however, I took the control box apart, put it back together, and the heater worked, I got piping hot water, turned it off, then on again, …

Get Price

Non Electric Gas Boiler | Terry Love Plumbing Advice

Jul 04, 2011 · For hydronic boilers 80% AFUE is achievable and legal with standing pilot ignition, but that requires pumps and some power to run the gas valves. Min-legal spec on steam is 75% AFUE, (also achievable with standing pilot, without forced-draft burners), but codes don't allow the type of gas valving used on millivolt systems, so it's still grid

Get Price

6. FBC BOILERS - Bureau of Energy Efficiency

CFBC boiler. The authors touch upon the design changes which the combustion in CFBC boilers. Variables like Bed height, process can also …

Get Price

Dedicated circuit for boiler | Electricians Forums

Mar 29, 2012 · When I rewire or on any new build I always wire the boiler on its own circuit. I have had 2 faults over the years where the pcb on the boiler has tripped the RCD on the ring main and where the fault was on he ring and so no boiler for a few hours, i think its easier to keep it seperate.After 2014 all new boilers will be electric anyway and will have a plug top like on the …

Get Price

New Boiler Connection to Gas Meter | Screwfix Community Forum

Dec 03, 2021 · The gas engineer installed a run of 22mm copper pipe from the new boiler to the gas meter cupboard. Boiler is working fine but my son has now found that his AGA gas cooker in the kitchen keeps extinguishing and the pilot continually needs to be reignited. The new boiler is rated at 35Kw and the AGA gas cooker is rated at 5Kw.

Get Price

boiler flue | DIYnot Forums

Aug 14, 2020 · when engineer did recent yearly service on my gas boiler he issued a do not use notice stating flue which exits roof is too close to roof vents, my landlord says it ok to use and at some time in future will sort problem are they right

Get Price

Boiler Gas Valve Problems And Faults - Heating | Gas

You'll need to get a Gas Safe boiler repair company to come and assess the situation with the valve. And, make sure it's a company that specialises in repairs. Across many online forums, you'll see various horror stories, where homeowners have replaced the gas valve, and even the PCB, only to find that the problem hasn't been fixed.

Get Price

Heat pumps vs Gas boilers - Page 3 — MoneySavingExpert Forum

Oct 20, 2021 · Banning gas boilers and petrol/diesel cars is far simpler. Primary legislation can be made to prohibit the sale of the item. In the current climate, Parliament is not going to block legislation to ban fossil fuel burning appliances/vehicles.

Get Price

Anyone have any problems with a Slant Fin Gas boiler

Oct 03, 2016 · Registered. Joined Mar 24, 2014. ·. 272 Posts. Discussion Starter · #1 · Oct 3, 2016. Only show this user. I have a price quote from a HVAC plumber to install a Slant Fin 140,000 BTU. gas boiler to replace our old oil McClain boiler. The HVAC plumber wants $5300 to install everything, including adding the chimney liner, plus this cost

Get Price

Boiler emergency shutdown | Mike Holt's Forum

Mar 12, 2021 · Miami, Florida, USA. Mar 11, 2021. #10. I don't know anything about residential boilers. Larger commercial fire tube boilers have safety circuits to shut the boiler down. Those are primary low water, secondary low water, primary high pressure, secondary high pressure, high and low gas pressure, lack of air pressure, and flame failure.

Get Price

My outdoor wood boiler build | Hearth.com Forums Home

Dec 23, 2018 · My outdoor wood boiler build. Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment. We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

Get Price

CFBC BOILER DETAILS PDF - 30doc.info

Jan 15, 2021 · CFBC BOILER DETAILS PDF. Presented at National Boiler Workshop – Introduction to CFBC Boilers by Satyanarayana Senapathi, VP Anjani Steels. ISGEC – CFBC boilers are easy to operate. ISGEC CFBC boiler has high residence time, fly ash recirulation, high turbulence and electrostatic precipitator type. Y Cube Engineered Solutions Private

Get Price

Regs on running / extending gas boiler flue in

Oct 06, 2016 · Regs on running / extending gas boiler flue in conservatory. Discussion in 'Plumbers' Talk' started by sospan, Sep 29, 2016. and not get a load of speculation from an internet forum, no matter how well intended, none of us can see what he intends to do. Dave does Gas, Oct 6, 2016 #14.

Get Price

Non Electric Gas Boiler | Terry Love Plumbing Advice

Jul 04, 2011 · For hydronic boilers 80% AFUE is achievable and legal with standing pilot ignition, but that requires pumps and some power to run the gas valves. Min-legal spec on steam is 75% AFUE, (also achievable with standing pilot, without forced-draft burners), but codes don't allow the type of gas valving used on millivolt systems, so it's still grid

Get Price

Boiler Gas Valve Problems And Faults - Heating | Gas

You'll need to get a Gas Safe boiler repair company to come and assess the situation with the valve. And, make sure it's a company that specialises in repairs. Across many online forums, you'll see various horror stories, where homeowners have replaced the gas valve, and even the PCB, only to find that the problem hasn't been fixed.

Get Price

Gas pipe sizing | Screwfix Community Forum

Mar 11, 2019 · Mike83 Screwfix Select. Pressure loss between gas meter and gas valve inlet shouldn't exceed 1mb. A quick calculation with 9m 22mm copper and 5 bends would be 0.922 mb. So if only 5 bends between meter and boiler then that's fine. But it will probably be a few more than 5. A 28mm pipe also give the option of increasing the size of the

Get Price

Richmond natural gas hot water boiler | DIY Home

Mar 27, 2016 · We have a 1960 Richmond (Rheem) natural gas hot water boiler to heat our 2800 sq. ft. house. Needless to say, this 300,000 BTU unit is a monster. It vents up the chimney with a 10-12 in. flue pipe! The previous owners even left the original manuals and warranties tucked away with the controls. When we got here, the pilot was still lit.

Get Price

Can a Homeowner install His Own Gas Boiler

Dec 11, 2021 · 2,206. Dec 9, 2021. #10. AFAIK, in England and Wales all gas boiler replacements and installations need to be registered at the Local Authority to meet with Building Regulations and it is illegal to install a boiler or a heating appliance into a property without a …

Get Price

Techno-economic analysis of PC versus CFB combustion

furnace, flue gases flow into a convective pass area, either directly above the furnace (tower boiler) or after a U-turn (two-pass boiler), where further heat exchange surfaces are placed (see Figure 1). PC boilers with capacities as high as 1300 …

Get Price

Boiler not lighting - DoItYourself.com Community Forums

Jan 04, 2022 · Get a voltmeter with two leads that has a dial that indicates the voltage between the two leads. Check for 24V at the gas valve, as suggested by Pete. If you're getting 24V, but the gas valve isn't opening, your gas valve might be shot. If you're not getting 24V when there is a call for heat and the boiler is cold, then suspect a bad thermostat

Get Price

Add on wood boiler to natural gas boiler possibility

Dec 08, 2008 · I have an older Peerless natural gas boiler, with updated honeywell electronics (Aquastat relay and ignition module). The whole house is on just on zone, with only one circulation pump. It is a hot water radiant heat system ( not steam) with cast iron radiators in each room.

Get Price

Small 10kg/s Sour gas boiler - [Oxygen Not Included

Nov 17, 2021 · Why would you need a 10kg/s boiler btw? 1kg NG feed 11 generators which means 8.8KW without counting the steam box's output to boot. I sometimes wonder on what you ppl spend all this energy on. In my most power hungry station I top 30KW with everything turned on at the same time (which is kinda hard to achieve anyways) o.o'

Get Price

10 Best Gas Boiler For Home of 2022

Potential sources can include buying guides for gas boiler for home, rating websites, word-of-mouth testimonials, online forums, and product reviews. Thorough and mindful research is crucial to making sure you get your hands on the best-possible gas boiler for home. Make sure that you are only using trustworthy and credible websites and sources.

Get Price

New Gas Boiler — MoneySavingExpert Forum

Dec 16, 2021 · 16 December 2021 at 3:46PM in Energy. We are going to get a new gas boiler as ours keeps breaking down so decided to bite the bullet. We have a 15kw at the moment and 8 rads ( but one is a double) 15kw apparently do up to 10 rads. Would it be more cost effective to get a bigger boiler that won't have to work so hard or just get another 15kw one.

Get Price

best sour gas boiler ever - Klei Entertainment Forums

Mar 20, 2021 · It would be nice to replace ceil with metal tiles and put steam turbines on top, because natural gas temperature ~400. Liquid pump could be constructed from anything, temperature is always below zero, 3 gas pumps for 2 aquatuners is enough, because 1 AT process around 1kg of oil per second (each liquid vent shows it work 11% of cycle, it mean, 1.1 …

Get Price

Old Gas Boiler - DoItYourself.com Community Forums

Sep 12, 2020 · Thermostatic Controls - Honeywell T9 Thermostat - Old Gas Boiler - Hello! I have a very simple heating system and need to replace the old thermostat with a smart thermostat. It is - Heating only, no AC, fans, and hot water radiators. - The new Thermostat - Honeywell T9, (includes power adapter for common wire, if

Get Price

Replacing a gas boiler with electric. - Electricians Forum

Mar 22, 2017 · Hi just after a bit of help ref a swap out as above for one of my builders at his home, He wants to replace gas boiler with an EHC 9kW Comet/Fusion boiler and has been quoted to have necessary 10mm T & E run from new meter to boiler position which is around a metre away. Thing is I don't have much experience as yet with boiler controls although following S …

Get Price

Dedicated circuit for boiler | Electricians Forums

Mar 29, 2012 · When I rewire or on any new build I always wire the boiler on its own circuit. I have had 2 faults over the years where the pcb on the boiler has tripped the RCD on the ring main and where the fault was on he ring and so no boiler for a few hours, i think its easier to keep it seperate.After 2014 all new boilers will be electric anyway and will have a plug top like on the …

Get Price

Gas boiler issue — Heating Help: The Wall

My gas boiler heat is not working. I can't get a pro to come out until Monday or Tuesday and I am hoping that someone might be able to help me with troubleshooting in the meantime. - One zone forced hot water cast iron radiators - Utica boiler from 1996 (MGB150HD) with honeywell aquastat (L8148E)

Get Price

flue gas analyser | Screwfix Community Forum

Nov 05, 2010 · Connect a suitable gas analyser to the sampling point on top of the boiler or into the flue terminal, if access is possible. Refer to Frame 41. For correct boiler operation the CO/CO2 ratio of the flue gas should not be greater than 0.004 ratio. If this is the case, and the gas input is at least 90% of the nominal, once compliance with the note

Get Price

Annual servicing required for gas boiler? - HVAC-Talk

Jan 03, 2009 · the gb is an excellent boiler. maintenance on a yearly schedule is required to keep your boiler clean and running at the top of its efficiency. neglect it and you will end up spending alot on repairs. would you drive your car with the pedal to the metal for three months and not at least change the oil? your boiler gets more than 3000 miles a year especially if your using a …

Get Price

Boiler modusnap gas valve replacement | Car Wash Forum

Dec 08, 2021 · So for over 25 years the BTUs from that specific modular boiler system were & are freed up for our three car wash Trane Glycol (higher temps) Units & all deicer & actual floor heat (higher temps) in the dog wash plus some baseboard-radiator in our laundromat & other back rooms. The Honeywell modulating gas valve from Raypak did make that

Get Price

CFBC BOILER DETAILS PDF - Flash PDF Container

Jan 30, 2021 · CFBC BOILER DETAILS PDF. Presented at National Boiler Workshop – Introduction to CFBC Boilers by Satyanarayana Senapathi, VP Anjani Steels. ISGEC – CFBC boilers are easy to operate. ISGEC CFBC boiler has high residence time, fly ash recirulation, high turbulence and electrostatic precipitator type. Y Cube Engineered Solutions Private

Get Price

Gas boiler flue extension | Screwfix Community Forum

Jan 19, 2014 · Screwfix Community Forum. Home Forums > Screwfix Community Forum > Engineers' Talk > Gas boiler flue extension. Discussion in 'Engineers' Talk' started by Mark8828, Jan 19, 2014. Mark8828 New Member.

Get Price

Gas Boiler Flue. | DIYnot Forums

Jun 26, 2020 · Had new gas boiler fitted last year, wall hung with outside wall flue all in same place as previous boiler,but more powerful. Have noticed steam from flue blows onto one side of house wall due to the strong west winds i get here, this is causing the paint on wall to bubble off and make plaster render damp.

Get Price

Forum: Pro's Forum: Hydronics/Boilers

Forum: Pro's Forum: Hydronics/Boilers. We've added a new forum for all of you rusty wetheads out there. This is the perfect place to discuss Hydronics and Boilers. There have been no posts in the last 30 days in this forum. Try using the controls below to …

Get Price

High efficiency gas boilers — Heating Help: The Wall

Every day of the heating season does not require the full output of the boiler. So example being on a 40* day you do not need the same btu output as on a 10* day. The mid efficiency boiler gives full output no matter what. There are some add ons like outdoor reset that helps a cast iron boiler be a little more efficient.

Get Price

Converting from oil to natural gas boiler - DoItYourself

Oct 24, 2021 · A typical oil to gas conversion includes replacing your existing oil heat boiler and all of the pipes, pumps and electrical components near the boiler. Converting from oil to gas can be costly, messy and disruptive to your home. conversion gas burner directly replaces only the oil burner on your oil heat boiler leaving all other system components in place saving thousands …

Get Price

flue gas analyser | Screwfix Community Forum

Nov 05, 2010 · Connect a suitable gas analyser to the sampling point on top of the boiler or into the flue terminal, if access is possible. Refer to Frame 41. For correct boiler operation the CO/CO2 ratio of the flue gas should not be greater than 0.004 ratio. If this is the case, and the gas input is at least 90% of the nominal, once compliance with the note

Get Price

Replacing Gas Boiler & Heater | Terry Love Plumbing Advice

Oct 04, 2021 · I've tried to fill my brain with a lot research this forum has to offer and I'm finding myself torn with which route to go. In the middle of a pretty big renovation to my house that was built in 67. Currently using an Ack-O-Matic Boiler that's …

Get Price

Gas Boiler - Liner Advice | Hearth.com Forums Home

Sep 22, 2021 · Gas Boiler - Liner Advice. Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment. We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

Get Price

Do I need a Gas Safe engineer to extend boiler flue

Jul 31, 2019 · 29 July 2019 at 9:38PM. Yes it's the most dangerous part of the boiler and must be installed by a gas safe registered engineer. It's a condensing boiler so even if there is water coming inside the flue its just going to go down the condensate trap, that's what it does with the condensate obviously.

Get Price

CFBC BOILER DETAILS PDF - 30doc.info

Jan 15, 2021 · CFBC BOILER DETAILS PDF. Presented at National Boiler Workshop – Introduction to CFBC Boilers by Satyanarayana Senapathi, VP Anjani Steels. ISGEC – CFBC boilers are easy to operate. ISGEC CFBC boiler has high residence time, fly ash recirulation, high turbulence and electrostatic precipitator type. Y Cube Engineered Solutions Private

Get Price

British Gas - Boiler Service Audit | AVForums

Jul 23, 2021 · Anyone else had their boiler serviced by British Gas and then received a letter to say the boiler needs a quality audit? Sounds to me like something dodgy is going on with the third party contractor they are using for boiler services. I now have to have more time off. LG 65C8, Anthem AVM70, Emotiva XPA Gen 3, Zidoo X20, B&W CM8 S2, B&W CMC S2

Get Price

New gas boiler problems | PlumbersForums.net

Dec 10, 2021 · Dec 10, 2021. #1. Hi all. Just installed a new baxi platinum on a new gas installation and everything is fine and the gas standing pressure is at 24mb when switching on the new boiler and trying to commission the boiler it draws gas and goes from 24mb down to 3mb and locks out. It is a medium pressure installation and the regulator is locking

Get Price

Central Heating Forum | PlumbersForums.net

Jan 08, 2022 · Questions and plumbing advice in the Central Heating Forum - Discuss all aspects of Central Heating Systems in this forum. Central Heating Systems Forum. Our forum is also known as the Boiler Forum, or Boiler Forum UK. If you're searching for the electrical aspects of Central Heating Systems then please visit the Electrical Forum ..

Get Price

converting propane boiler to natural gas | DIY Home

Jan 15, 2009 · As to testing for cracks no real way on an old boiler you need heat and pressure and water going through the tubes. If the boiler has set for a long time 3 or more years Rust will be an issue. The conversion is simple change the spuds the regulator spring possibly the burners. Then set the gas pressure. Getting the kit would be a trick.

Get Price

A Review of Some Operation and Maintenance Issues of CFBC

The various challenges that are thrown at the refractory in a CFBC boiler have been well documented [1][2] [3] [4][5]. The demands of quantity and quality of …

Get Price

Gas Boiler Problem — boards.ie - Now Ye're Talkin'

Jan 10, 2022 · Gas Boiler Problem. Kefid22 10:30pm #1. sandra_b. Registered Users Posts: 245 . Join Date: September 2010. Posts: 225. My gas boiler was not working properly last week- I could not switch it off unless going to winter/summer mode. On winter mode it was working ok, but I could not switch it off unless setting it to summer mode.

Get Price
Hey, let me help you!